Design stage

SuVayu 2K

Cleaner air for every room on the AHU.

A 2,000 CFM (3,400 m³/h) unit fitted in the return duct of an existing air-handling unit. It treats particles, gases and microbes without HEPA filters.

For: Hospitals (OPD, wards, ICU corridors), shopping malls, food courts, campuses and offices

Bought as: Unit and installation per AHU, with AMC; first sites as monitored pilots

SuVayu units beside a hospital building, concept Concept render
Hospital deployment, concept visualisation

What it does

Central air conditioning recirculates most of the air in a hospital or a mall, and the fine particles, odours and microbes go round with it.

SuVayu 2K sits in the return duct of the air-handling unit (AHU) and treats the whole air stream before it returns to supply. Low pressure drop, no HEPA filters to clog and replace.

Why it is different

  • Treats gases and microbes as well as particles; conventional AC filtration treats particles only.
  • Fits the AHU you already have; no new ducting.
  • No HEPA dependency, so lower pressure drop and simpler maintenance.
  • Monitoring and reporting built in, for infection-control and facilities teams.

Specification

Key figures

Design values. No unit has been measured yet.

Airflow
2,000 CFM (≈ 3,400 m³/h)
Room refresh
≈ 38 air changes per hour (ACH) in a typical common room
Treats
Particles, gases and microbes
Footprint
0.8 × 0.8 × 1.3 m
Service
Scheduled media change, no HEPA

How it works

From survey to service

  1. Site survey

    AHU capacity, the rooms it serves and the air-change targets.

  2. Sizing

    One unit per AHU return, sized to its airflow.

  3. Installation

    Fitted in the existing return duct; no new ducting.

  4. Measurement and service

    Readings before and after, then scheduled media changes under an AMC.

Status & evidence

Status: design stage

Specification and drawings are complete. We are selecting a first hospital or mall for a monitored installation. The pilot protocol measures against WHO PM2.5 guideline values and ASHRAE 170 air-change practice for healthcare spaces.

SuVayu units beside a shopping mall, concept Concept render
Shopping mall deployment, concept visualisation

Commercial model

How it is bought

Priced per site after sizing. Every supply comes with an annual maintenance contract (AMC) option and a measurement plan, so you see inlet and outlet readings for your own installation.

  • Unit supply and installation, per AHU
  • AMC: scheduled media replacement
  • Optional monitoring with reports for infection-control audits
  • First sites: monitored pilot installation on pilot terms

Questions we get

Is this an air purifier?

No. It is an AHU component. It treats the whole air stream of the unit, so every room on that AHU gets the same air.

Will it affect the AC performance?

The unit is designed for low pressure drop so the existing fans can handle it. Airflow is verified at the complete operating condition on site.

How often is service needed?

Intervals depend on the site and are set during the pilot.

Does it replace HEPA in an operating theatre or ICU?

No. Operating theatres and ICUs keep their terminal HEPA filtration. SuVayu 2K treats the wards, OPD and common areas on the same AHU.

Talk to us about SuVayu 2K

Send your site details or a stack report. We reply within two working days.